400kW 500kVA Heavy Duty Mobile Trailer Diesel Generator with WP12ZLD Engine
Trailer Type

400KW / 500kVA Mobile Trailer Diesel Generator

Highway-Ready Mobility | Engine: WP12ZLD | SKU: YMDL-400GF-TRAILER

$10,633
FOB China ยท Standard Package
Standard Package Includes
  • Half-Copper Brushed Alternator
  • Industrial Diagnostics Controller
  • Heavy-duty Trailer Chassis, IP44
  • Base Fuel Tank, โ‰ฅ8h Runtime at Full Load
  • Full Auto System (ATS) โ€” Standard
400kW
Prime Output
Trailer
Frame Style
3860 kg
Dry Mass
IP44
Enclosure Rating

Build Your Own Configuration

Custom builds are quoted individually via WhatsApp โ€” pricing shown below for full transparency.

Alternator
Controller
Selected configuration
Default (no upgrades)
$10,633

Engineering Data & Specifications

MetricPerformance Values
System SKUYMDL-400GF-TRAILER
Rated Power (Standby)400 kW / 500 kVA
Rated Power (Prime)360 kW / 450 kVA
Rated Voltage400V / 230V (3-Phase 4-Wire)
Rated Frequency50 Hz
Power Factor0.8 (Lagging)
Engine ModelWP12ZLD (Weifang)
Engine Type4-Stroke, Water-Cooled, In-line 4-Cylinder
Displacement4.15 L
Rated Engine Speed1500 RPM
AlternatorHalf-Copper Brushed (Default)
ControllerIndustrial Diagnostics System (Default)
Frame ConstructionHeavy-duty trailer chassis
IP RatingIP44 (Requires indoor/sheltered installation)
Fuel Tank CapacityBase tank for โ‰ฅ 8 hours at full load
Dry Weight3860 kg
Dimensions (L ร— W ร— H)3850 ร— 1800 ร— 2610 mm
Starting SystemElectric Start (12V / 24V)
Cooling SystemWater-Cooled with Radiator
CertificationConforms to ISO 8528 Design Standard / CE
Four Protection Engine Safety System - Auto Shutdown Controller
โš™๏ธ Built-In Industrial Safety

Digital Overwatch โ€” 4-Point Engine Protection

At 400kW, a missed fault signal means costly downtime or permanent engine damage. The WP12ZLD's onboard controller monitors four critical parameters simultaneously and shuts down the unit before damage occurs โ€” no operator intervention required.

Why it matters: A sudden drop in oil pressure or a spike in coolant temperature often goes unnoticed until it's too late. This module acts as an automated on-site mechanic โ€” always watching, always ready to intervene.

  • ๐Ÿ›ข๏ธ
    Low Oil Pressure Shutdown
    Detects pressure drops below safe threshold and cuts the engine immediately to prevent bearing seizure.
  • ๐ŸŒก๏ธ
    High Temperature Shutdown
    Monitors coolant temperature in real time and shuts down the unit if the radiator is overwhelmed.
  • โšก
    Over-Speed Protection
    Locks engine speed to 1500 RPM and triggers emergency shutdown if runaway conditions are detected.
  • ๐Ÿ”Œ
    Over-Voltage / Short Circuit
    Isolates the alternator from downstream load faults before current spikes can damage the windings.
โšก
Need seamless switchovers? Add the ATS module from our configurator. It senses grid outages and assumes the facility load completely hands-free.

500kVA Trailer Generator โ€” Key Highlights

๐Ÿš›

Highway-Ready Trailer Chassis

Mounted on a purpose-built heavy-duty trailer with a standard ring hitch, the unit tows at up to 40 km/h on paved roads. No crane, no concrete pad โ€” reposition 3860 kg of generator capacity with a standard truck.

โš™๏ธ

Weifang WP12ZLD Engine

4-stroke, water-cooled, in-line 4-cylinder engine with a 4.15 L displacement. Rated at 1500 RPM for 50 Hz output. The WP12ZLD is a proven workhorse across African and Middle Eastern markets known for long service intervals and widely available spare parts.

๐Ÿ”„

Standby & Prime Dual Rating

Rated at 400 kW / 500 kVA standby and 360 kW / 450 kVA prime. The prime rating reflects continuous 24/7 operation at sustained load โ€” critical for quarry sites, mining camps, and construction projects where the generator is the sole power source.

๐Ÿ›ก๏ธ

IP44 Enclosure โ€” Outdoor Capable

IP44 protection guards against solid particle ingress and water splashing from any direction. Suitable for open-air deployment on construction sites and quarries. A simple canopy or lean-to shelter extends service life further in heavy-rain environments.

๐Ÿ•—

โ‰ฅ 8-Hour Runtime at Full Load

The base fuel tank is sized to deliver at least 8 continuous hours of operation at 100% load without refuelling. Extended tank options are available โ€” contact us for overnight or 12-hour autonomy configurations.

๐Ÿ”

Full Auto ATS โ€” Standard on 200kW+

Automatic Transfer Switch (ATS) is included as standard equipment. It detects mains outages and transfers the full 500 kVA load in seconds โ€” no manual intervention needed. Ideal for hospitals, data centres, and process facilities where downtime is not an option.

๐Ÿ”ฉ

Heavy-Duty Stabiliser Jacks

Four corner stabiliser jacks level and lock the trailer on uneven ground, eliminating chassis flex that can skew oil pressure readings. Extend the jacks before start-up on any surface that is not paved or compacted gravel.

๐Ÿ“œ

ISO 8528 & CE Certified

Manufactured to ISO 8528 performance standards and carries CE marking for European and international tender compliance. Documentation package โ€” test reports, declaration of conformity, and engine certificates โ€” supplied with every unit.

Physical Dimensions & Weight

3850 mm
Length
1800 mm
Width
2610 mm
Height
3860 kg
Net Weight

Frequently Asked Questions

What is the difference between the standby rating and the prime rating?

Standby rating (400 kW / 500 kVA) is the maximum output the generator can sustain for short-duration emergencies โ€” typically up to 200 hours per year at variable load. Prime rating (360 kW / 450 kVA) is for unlimited continuous operation where the generator is the primary power source. If the unit will run daily on a construction site or mining camp, size your loads against the prime figure.

What is the maximum towing speed for the trailer?

The trailer is rated for road towing at up to 40 km/h on paved or well-maintained surfaces. Always drain condensate from the fuel tank before a long tow, and extend the four stabiliser jacks before start-up once the unit is repositioned and parked on level or compacted ground.

Is this unit suitable for outdoor installation?

The IP44-rated enclosure protects against dust and water splash, making it suitable for open-air construction sites and quarries. For prolonged deployment in tropical or high-rainfall environments, a simple canopy or lean-to shelter is recommended to extend service intervals and protect the control panel from direct rain exposure.

How long will the generator run on a full tank?

The base fuel tank is sized for a minimum of 8 hours of continuous operation at 100% load. Actual runtime will be longer at partial loads. Extended tank configurations for 12-hour or overnight autonomy are available โ€” contact our sales team with your load profile and we will quote the appropriate option.

Does it come with an Automatic Transfer Switch (ATS)?

Yes. ATS is standard equipment on all units rated 200kW and above, including this model. The system monitors the incoming mains supply and transfers the full load to the generator within seconds of detecting an outage โ€” fully hands-free. No additional wiring or external ATS cabinet is required for standard installations.

What alternator options are available, and which should I choose?

Four options are available: Half-Copper Brushed (base), Full-Copper Brushed (+$123), Half-Copper Brushless (+$123), and Full-Copper Brushless (+$282). For heavy industrial use or harsh ambient temperatures, the Full-Copper Brushless alternator offers the best heat dissipation, lowest maintenance (no brush wear), and longest winding life. Use the configurator above to update the price accordingly.

What certifications does the unit carry?

The generator is certified to ISO 8528 (reciprocating internal combustion engine driven alternating current generating sets) and carries CE marking. A documentation package including test reports, declaration of conformity, and engine certificates is supplied with every unit โ€” suitable for tender submission and customs clearance.

What voltage and frequency outputs are available?

The standard configuration outputs 400V / 230V at 50 Hz via a 3-phase 4-wire system at 0.8 power factor. Custom voltage and 60 Hz configurations are available for export markets โ€” contact us before ordering if your site operates on a different standard.

What engine protection systems are built in?

The WP12ZLD controller monitors four parameters and triggers automatic shutdown if any threshold is breached: low oil pressure, high coolant temperature, over-speed (above 1500 RPM), and over-voltage or short-circuit conditions. All four protections are active from the moment the engine starts โ€” no additional wiring or programming is required on site.

Are wholesale pricing and OEM configurations available?

Yes. Volume discounts apply to orders of 3 units or more. OEM options include custom canopy colours, logo badging, alternative engine brands, and container-loaded mixed orders. Contact our team via the quote form or WhatsApp for a written bulk pricing proposal within one business day.

Ready to Order or Need a Custom Quote?

Contact our team for bulk pricing, upgrade configurations, shipping estimates, and OEM options.

Build Custom Configuration