30kW 38kVA Silent Type Weifang Diesel Generator with 6126ZLD Engine
Silent Type

200kW / 250kVA Silent Type Diesel Generator

250kVA industrial silent generator for large industrial facilities | Engine: 6126ZLD | SKU: YMDL-200GF-SILENT

The 200kW silent generator is an industrial-grade power solution for large factories, shopping malls, and industrial parks requiring high-capacity, low-noise backup or prime power.

$6,046
FOB China · Default Configuration
Alternator
Controller
Contact Us for Wholesale Quote
30kW
Prime Output
Silent Canopy
Frame Style
2466 kg
Dry Mass
IP44
Enclosure Rating

Engineering Data & Specifications

MetricPerformance Values
System SKUYMDL-200GF-SILENT
Rated Power (Standby)30 kW / 38 kVA
Rated Power (Prime)180 kW / 225 kVA
Rated Voltage400V / 230V (3-Phase 4-Wire)
Rated Frequency50 Hz
Power Factor0.8 (Lagging)
Engine Model6126ZLD
Engine Type4-Stroke, Water-Cooled, In-line 4-Cylinder
Displacement4.15 L
Rated Engine Speed1500 RPM
AlternatorHalf-Copper Brushed (Default)
ControllerIndustrial Diagnostics System (Default)
Frame ConstructionAcoustic steel canopy
IP RatingIP44 (Requires indoor/sheltered installation)
Fuel Tank CapacityBase tank for ≥ 8 hours at full load
Dry Weight2466 kg
Dimensions (L × W × H)3600 × 1300 × 1910 mm
Starting SystemElectric Start (12V / 24V)
Cooling SystemWater-Cooled with Radiator
CertificationISO 8528 / CE
Four Protection Engine Safety System - Auto Shutdown Controller
⚙️ Built-In Industrial Safety

Smart Engine Diagnostics & Auto-Shutdown

When running exposed equipment in harsh environments like farms, quarries, or factory floors, manual monitoring isn't practical. Our industrial-grade controller actively watches the engine's vital signs and will physically kill the engine long before an anomaly turns into an overhaul.

Why it matters: Industrial facilities operating 200kW+ generators carry significant capital exposure. An engine failure caused by neglected warning signs — low oil pressure, rising coolant temperature — can result in repair costs that exceed the generator's purchase price. The Four Protection System eliminates this risk by intervening automatically before damage occurs, even when operators are focused on production rather than generator monitoring.

Operating an open base-frame generator requires reliable fail-safes. Whether a stray piece of debris blocks the radiator or a sudden electrical fault occurs downstream on your site, the control module instantly isolates the problem, stopping the engine dead in tracks to preserve its mechanical integrity.

  • 🛢️
    Lubrication Loss Detection
    Monitors oil viscosity and pressure in real-time. If levels drop to dangerous zones, it stalls the engine instantly to avoid scored cylinders.
  • 🌡️
    Thermal Overload Cut-Off
    Reads radiator output heat. Triggers an immediate halt if the cooling system is compromised, sparing the block from heat deformation.
  • Runaway RPM Prevention
    Instantly throttles and cuts the fuel injector pump if the load suddenly drops and the engine attempts to over-rev.
  • 🔌
    Electrical Surge Isolation
    Safeguards the alternator windings. Detects external short circuits and kills power delivery before the copper burns out.
Need seamless switchovers? Add the ATS module from our configurator. It senses grid outages and assumes the facility load completely hands-free.

Core Advantages of the Silent Canopy Build

🛡️

Weatherproof Steel Enclosure

Constructed with cold-rolled steel and electrostatic powder coating, providing IP44-equivalent weather protection suitable for permanent outdoor installation.

🔇

Acoustic Noise Damping

Lined with high-density flame-retardant sound-absorbing foam to significantly reduce engine noise emissions for noise-sensitive areas.

👁️

6126ZLD — Heavy Industrial Engine Platform

The 6126ZLD engine platform steps up to a larger 126mm bore, delivering the torque density needed for heavy industrial loads — large compressors, high-capacity pumps, arc welders, and multiple simultaneous motor starts. Its heavy-duty construction is designed for sustained operation at high load factors without the derating required on smaller platforms.

📉

Container-Shippable Industrial Power

The 200kW silent generator ships in a standard 20-foot container. For buyers importing to remote regions or island markets, this standard shipping footprint simplifies logistics, reduces freight costs, and avoids the special handling requirements of out-of-gauge cargo that affect larger units.

Physical Dimensions & Weight

3600 mm
Length
1300 mm
Width
1910 mm
Height
2466 kg
Net Weight

Frequently Asked Questions

What is special about the 6126ZLD engine?

The 6126ZLD is a 6-cylinder engine with 126mm bore — significantly larger than the 105mm and 155mm engines used in smaller models. It is designed for heavy industrial use and rated for both standby and prime power applications. The larger displacement means lower RPM stress at equivalent power output, translating to longer engine life.

Is 200kW enough for a large shopping mall?

For a shopping mall, 200kW typically covers emergency lighting, escalators, HVAC for common areas, and critical retail anchor tenant backup circuits. For full mall power including all tenant loads, parallel operation of multiple units or a larger 300–500kW unit is required. We recommend a load calculation before specifying.

What is the weight and transport requirement for the 200kW unit?

The 200kW silent generator weighs approximately 2,466kg. Standard transport requires a flatbed truck with crane offloading capability. The unit ships in a standard 20ft container. We can advise on foundation and anti-vibration mounting specifications on request.

Ready to Order or Need a Custom Quote?

Contact our team for bulk pricing, upgrade configurations, shipping estimates, and OEM options.

Contact Us for Wholesale Quote