30kW 38kVA Silent Type Weifang Diesel Generator with R6105AZLD Engine
Silent Type

100kW / 125kVA Silent Type Diesel Generator

Best-selling 125kVA silent generator for industrial and commercial use | Engine: R6105AZLD | SKU: YMDL-100GF-SILENT

Our best-selling model — the 100kW silent generator is the most requested unit for mid-size factories, warehouses, and commercial facilities across Africa, Southeast Asia, and the Middle East.

$3,592
FOB China · Default Configuration
Alternator
Controller
Contact Us for Wholesale Quote
30kW
Prime Output
Silent Canopy
Frame Style
1348 kg
Dry Mass
IP44
Enclosure Rating

Engineering Data & Specifications

MetricPerformance Values
System SKUYMDL-100GF-SILENT
Rated Power (Standby)30 kW / 38 kVA
Rated Power (Prime)90 kW / 112 kVA
Rated Voltage400V / 230V (3-Phase 4-Wire)
Rated Frequency50 Hz
Power Factor0.8 (Lagging)
Engine ModelR6105AZLD
Engine Type4-Stroke, Water-Cooled, In-line 4-Cylinder
Displacement4.15 L
Rated Engine Speed1500 RPM
AlternatorHalf-Copper Brushed (Default)
ControllerIndustrial Diagnostics System (Default)
Frame ConstructionAcoustic steel canopy
IP RatingIP44 (Requires indoor/sheltered installation)
Fuel Tank CapacityBase tank for ≥ 8 hours at full load
Dry Weight1348 kg
Dimensions (L × W × H)2900 × 1100 × 1600 mm
Starting SystemElectric Start (12V / 24V)
Cooling SystemWater-Cooled with Radiator
CertificationISO 8528 / CE
Four Protection Engine Safety System - Auto Shutdown Controller
⚙️ Built-In Industrial Safety

Smart Engine Diagnostics & Auto-Shutdown

When running exposed equipment in harsh environments like farms, quarries, or factory floors, manual monitoring isn't practical. Our industrial-grade controller actively watches the engine's vital signs and will physically kill the engine long before an anomaly turns into an overhaul.

Why it matters: In a factory environment, an uncontrolled engine failure can halt an entire production line — causing losses that far exceed the cost of the generator itself. The Four Protection System prevents cascade failures by shutting the engine down safely the moment any critical parameter is exceeded, keeping repair costs predictable and production downtime short.

Operating an open base-frame generator requires reliable fail-safes. Whether a stray piece of debris blocks the radiator or a sudden electrical fault occurs downstream on your site, the control module instantly isolates the problem, stopping the engine dead in tracks to preserve its mechanical integrity.

  • 🛢️
    Lubrication Loss Detection
    Monitors oil viscosity and pressure in real-time. If levels drop to dangerous zones, it stalls the engine instantly to avoid scored cylinders.
  • 🌡️
    Thermal Overload Cut-Off
    Reads radiator output heat. Triggers an immediate halt if the cooling system is compromised, sparing the block from heat deformation.
  • Runaway RPM Prevention
    Instantly throttles and cuts the fuel injector pump if the load suddenly drops and the engine attempts to over-rev.
  • 🔌
    Electrical Surge Isolation
    Safeguards the alternator windings. Detects external short circuits and kills power delivery before the copper burns out.
Need seamless switchovers? Add the ATS module from our configurator. It senses grid outages and assumes the facility load completely hands-free.

Core Advantages of the Silent Canopy Build

🛡️

Weatherproof Steel Enclosure

Constructed with cold-rolled steel and electrostatic powder coating, providing IP44-equivalent weather protection suitable for permanent outdoor installation.

🔇

Acoustic Noise Damping

Lined with high-density flame-retardant sound-absorbing foam to significantly reduce engine noise emissions for noise-sensitive areas.

👁️

R6105AZLD Long-Stroke — Higher Torque, Better Efficiency

The 'L' designation in R6105AZLD means long-stroke: a larger piston travel distance that produces higher torque at lower RPM. In practice, this means better performance under heavy factory loads, less fuel consumption at partial load, and lower cylinder wear over time compared to short-stroke engines of equivalent power.

📉

Best-Seller: Backed by the Widest Parts Network

The R6105 engine series is the most widely deployed generator engine in our range. Its widespread adoption means parts — injectors, pumps, filters, belts — are stocked by distributors across Africa, Southeast Asia, and the Middle East. Your local diesel mechanic almost certainly knows this engine.

Physical Dimensions & Weight

2900 mm
Length
1100 mm
Width
1600 mm
Height
1348 kg
Net Weight

Frequently Asked Questions

Why is the 100kW model the best seller?

The 100kW / 125kVA range is the sweet spot for most mid-size commercial and industrial operations. It provides enough power for a full factory floor or large commercial building while remaining cost-effective. The R6105AZLD engine has an extensive global service network, making spare parts and local technical knowledge widely available.

Is 100kW sufficient for a medium-sized factory?

For a factory with machinery loads totalling 60–80kW (motors, compressors, welding equipment) plus lighting and office loads, 100kW provides comfortable headroom. We recommend keeping running load at 70–80% of rated capacity for optimal engine longevity.

What does AZLD mean in the engine model R6105AZLD?

In Weichai engine nomenclature: R = Ricardo licence, 6105 = 6-cylinder 105mm bore, A = turbocharged, Z = dedicated generator application, L = larger displacement long-stroke variant, D = electronic control. The L designation is what sets this engine apart from the standard R6105AZD.

Ready to Order or Need a Custom Quote?

Contact our team for bulk pricing, upgrade configurations, shipping estimates, and OEM options.

Contact Us for Wholesale Quote