500kW / 625kVA Open Type Diesel Generator
Exposed Engine Architecture | Engine: WP13ZLD | SKU: YMDL-500GF-OPEN
- Half-Copper Brushed Alternator
- Industrial Diagnostics Controller
- Heavy-duty Steel Base Frame, IP23
- Base Fuel Tank, β₯8h Runtime at Full Load
- Full Auto System (ATS) β Standard
Build Your Own Configuration
Custom builds are quoted individually via WhatsApp β pricing shown below for full transparency.
Engineering Data & Specifications
| Metric | Performance Values |
|---|---|
| System SKU | YMDL-500GF-OPEN |
| Rated Power (Standby) | 500 kW / 625 kVA |
| Rated Power (Prime) | 450 kW / 562 kVA |
| Rated Voltage | 400V / 230V (3-Phase 4-Wire) |
| Rated Frequency | 50 Hz |
| Power Factor | 0.8 (Lagging) |
| Engine Model | WP13ZLD (Weifang) |
| Engine Type | 4-Stroke, Water-Cooled, In-line 4-Cylinder |
| Displacement | 4.15 L |
| Rated Engine Speed | 1500 RPM |
| Alternator | Half-Copper Brushed (Default) |
| Controller | Industrial Diagnostics System (Default) |
| Frame Construction | None (Heavy-duty steel base frame) |
| IP Rating | IP23 (Requires indoor/sheltered installation) |
| Fuel Tank Capacity | Base tank for β₯ 8 hours at full load |
| Dry Weight | 2500 kg |
| Dimensions (L Γ W Γ H) | 3200 Γ 1150 Γ 1600 mm |
| Starting System | Electric Start (12V / 24V) |
| Cooling System | Water-Cooled with Radiator |
| Certification | Conforms to ISO 8528 Design Standard / CE |
500kW Diesel Generator Command
Managing the 500kW Diesel Generator expertly.
Why it matters: Heavy-duty open generators often run in hot, dusty rooms. A sudden drop in oil or spike in temperature goes unnoticed until it's too late. This module is your automated mechanic.
Operating an open base-frame generator requires reliable fail-safes. Whether a stray piece of debris blocks the radiator or a sudden electrical fault occurs downstream on your site, the control module instantly isolates the problem, stopping the engine dead in tracks to preserve its mechanical integrity.
-
Oil CommandRules 500kW Diesel Generator pressure.
-
Heat CommandMasters 500kW Diesel Generator temp.
-
RPM CommandControls 500kW Diesel Generator revs.
-
Grid CommandProtects 500kW Diesel Generator load.
Core Advantages of the Open-Frame Build
Heavy-Duty Skid Base
Built on a rigid, vibration-isolating steel frame. It ensures structural integrity during heavy-load operation and simplifies forklift handling or permanent concrete pad installation.
Maximum Cooling Efficiency
Without a restrictive canopy, the oversized radiator and cooling fan benefit from unrestricted ambient airflow, drastically reducing the risk of overheating in high-temperature engine rooms.
Unrestricted Maintenance Access
Mechanics have 360-degree access to all engine components. Oil changes, filter replacements, and alternator inspections can be performed in half the time compared to enclosed units.
Highest kW-to-Cost Ratio
By eliminating the cost of a weather-proof enclosure, your investment goes entirely toward raw megawatt-class power generation. Itβs the most cost-effective solution for dedicated indoor generator facilities.
Seamless Plant Integration
The open architecture makes it incredibly straightforward to pipe external exhaust systems, connect high-capacity bulk fuel tanks, and integrate with existing industrial electrical layouts.
WP13ZLD Core Reliability
Powered by the proven Weifang WP13 engine block. Renowned for its massive displacement, heavy-duty torque tolerance, and the global availability of affordable replacement parts.
Physical Dimensions & Weight
Frequently Asked Questions
Is 500kW enough power for my facility?
A typical 500kW generator can power lighting, refrigeration, water pumps, and several air conditioning units simultaneously. For a standard facility under 300mΒ², 500kW is usually sufficient for essential loads. We recommend listing your equipment wattage for a precise sizing check.
How much fuel does the 500kW generator consume per hour?
At full load, the WP13ZLD engine consumes approximately 7β8 litres of diesel per hour. At 75% load (typical operating condition), fuel consumption drops to around 5.5β6.5 litres/hour. The built-in base tank supports β₯8 hours of runtime at full load.
Can I install this open type unit outdoors permanently?
No. Open type generators must be installed indoors in a dedicated, well-ventilated generator room or under a protective shelter. They are not waterproof and should not be exposed to direct rain or extreme weather without a canopy.
What does the "Four Protection System" controller do?
The standard controller monitors four critical parameters in real-time: oil pressure, coolant temperature, engine over-speed, and over-current. If any parameter exceeds the safe threshold, the controller will automatically shut down the engine to prevent damage. It can be upgraded to a Full Auto (ATS) system for unmanned, automatic operation.
What is the difference between the brushed and brushless alternator options?
The default half-copper brushed alternator requires periodic brush replacement but is cost-effective for standard applications. The brushless variants (half-copper or full-copper) eliminate brush wear, provide cleaner power output, and are more suitable for sensitive electronics or installations with minimal maintenance access.
Do you offer wholesale or bulk order pricing?
Yes. As a factory-direct supplier, we offer competitive wholesale pricing for bulk orders. The listed price of $11,169 reflects the default single-unit FOB China price. Please contact us with your quantity and specifications for a tailored quotation.
Ready to Order or Need a Custom Quote?
Contact our team for bulk pricing, upgrade configurations, shipping estimates, and OEM options.