Skip to main content
kurt diesel Generators logo kurt diesel Generators logo
$0,00 0

Cart

No products in the cart.

Continue shopping
40kW 50kVA Open Type Weifang Diesel Generator with ZH4100ZD Engine
Open Type

40kW / 50kVA Open Type Diesel Generator

Exposed Engine Architecture | Engine: ZH4100ZD | SKU: YMDL-40GF-OPEN

Unleash continuous 40kW Diesel Generator performance tailored for medium-duty facilities.

$1,633
FOB China · Default Configuration
Alternator
Controller
Contact Us for Wholesale Quote
40kW
Prime Output
Skid
Frame Style
600 kg
Dry Mass
IP23
Enclosure Rating

Engineering Data & Specifications

MetricPerformance Values
System SKUYMDL-40GF-OPEN
Rated Power (Standby)40 kW / 50 kVA
Rated Power (Prime)36 kW / 45 kVA
Rated Voltage400V / 230V (3-Phase 4-Wire)
Rated Frequency50 Hz
Power Factor0.8 (Lagging)
Engine ModelZH4100ZD (Weifang)
Engine Type4-Stroke, Water-Cooled, In-line 4-Cylinder
Displacement4.15 L
Rated Engine Speed1500 RPM
AlternatorHalf-Copper Brushed (Default)
ControllerIndustrial Diagnostics System (Default)
Frame ConstructionNone (Heavy-duty steel base frame)
IP RatingIP23 (Requires indoor/sheltered installation)
Fuel Tank CapacityBase tank for ≥ 8 hours at full load
Dry Weight600 kg
Dimensions (L × W × H)1700 × 600 × 1100 mm
Starting SystemElectric Start (12V / 24V)
Cooling SystemWater-Cooled with Radiator
CertificationISO 8528 / CE
Four Protection Engine Safety System - Auto Shutdown Controller
⚙️ Built-In Industrial Safety

40kW Diesel Generator Safety Network

Protecting your 40kW Diesel Generator investment with real-time automated intervention.

Why it matters: Heavy-duty open generators often run in hot, dusty rooms. A sudden drop in oil or spike in temperature goes unnoticed until it's too late. This module is your automated mechanic.

Operating an open base-frame generator requires reliable fail-safes. Whether a stray piece of debris blocks the radiator or a sudden electrical fault occurs downstream on your site, the control module instantly isolates the problem, stopping the engine dead in tracks to preserve its mechanical integrity.

  • 🛢️
    40kW Oil Security
    Maintains optimum pressure for the ZH4100ZD block.
  • 🌡️
    Coolant Guard
    Halts the 40kW Diesel Generator instantly if temps rise.
  • RPM Governor
    Stabilizes the 40kW output under shifting loads.
  • 🔌
    Surge Block
    Cuts 50kVA surges before damaging your grid.
Need seamless switchovers? Add the ATS module from our configurator. It senses grid outages and assumes the facility load completely hands-free.

Core Advantages of the Open-Frame Build

🏗️

Compact Base Frame

Fits into tight spaces while delivering 50kVA.

🌬️

High-Flow 40kW Cooling

The open design ensures this 40kW Diesel Generator breathes perfectly in plant rooms.

👁️

Accessible Maintenance

Service this 40kW Diesel Generator without canopy constraints.

📉

Cost-Effective 40kW Power

Skip the canopy cost and get pure 40kW Diesel Generator output.

🏭

Extended 40kW Runtime

Integrated tank fuels your 40kW Diesel Generator for hours.

⚙️

ZH4100ZD Dependability

A turbocharged core giving this 40kW Diesel Generator massive torque.

Physical Dimensions & Weight

1700 mm
Length
600 mm
Width
1100 mm
Height
600 kg
Net Weight

Frequently Asked Questions

Is 40kW enough power for my facility?

A typical 40kW generator can power lighting, refrigeration, water pumps, and several air conditioning units simultaneously. For a standard facility under 300m², 40kW is usually sufficient for essential loads. We recommend listing your equipment wattage for a precise sizing check.

How much fuel does the 40kW generator consume per hour?

At full load, the ZH4100ZD engine consumes approximately 7–8 litres of diesel per hour. At 75% load (typical operating condition), fuel consumption drops to around 5.5–6.5 litres/hour. The built-in base tank supports ≥8 hours of runtime at full load.

Can I install this open type unit outdoors permanently?

No. Open type generators must be installed indoors in a dedicated, well-ventilated generator room or under a protective shelter. They are not waterproof and should not be exposed to direct rain or extreme weather without a canopy.

What does the "Four Protection System" controller do?

The standard controller monitors four critical parameters in real-time: oil pressure, coolant temperature, engine over-speed, and over-current. If any parameter exceeds the safe threshold, the controller will automatically shut down the engine to prevent damage. It can be upgraded to a Full Auto (ATS) system for unmanned, automatic operation.

What is the difference between the brushed and brushless alternator options?

The default half-copper brushed alternator requires periodic brush replacement but is cost-effective for standard applications. The brushless variants (half-copper or full-copper) eliminate brush wear, provide cleaner power output, and are more suitable for sensitive electronics or installations with minimal maintenance access.

Do you offer wholesale or bulk order pricing?

Yes. As a direct manufacturer, we offer competitive wholesale pricing for bulk orders. The listed price of $1,633 reflects the default single-unit FOB China price. Please contact us with your quantity and specifications for a tailored quotation.

Ready to Order or Need a Custom Quote?

Contact our team for bulk pricing, upgrade configurations, shipping estimates, and OEM options.

Contact Us for Wholesale Quote